English | 中文版 | 手机版 企业登录 | 个人登录 | 邮件订阅
当前位置 > 产品目录 > 实验动物/细胞株 > 动物器具 > Wmicrotracker ONE
Wmicrotracker ONE
英文名称:Wmicrotracker ONE总访问:166
国产/进口:进口半年访问:16
产地/品牌:阿根廷/phylumtech产品类别:动物器具
规       格:Phylumtech 最后更新:2025-2-23
货       号:Wmicrotracker ONE
参考报价:USD18000
立即询价 电话咨询
[发表评论] [本类其他产品] [本类其他供应商] [收藏]
销售商: 上海伯建生物科技有限公司 查看该公司所有产品 >>
  • 产品介绍
  • 公司简介
page1image338369760 page1image338373904
page2image338371888 page2image338376368 page2image338382224page2image338387488 page2image338387824 page2image338392976 page2image338336768 page2image338345616 page2image338270672
page2image2636223776 page2image2636232512

Many biological assays are complex to perform, requiring great manipulation skills and analysis time. This makes the work tedious and limits experiments based on their level of difficulty. Therefore, at Phylumtech, our vision is to provide unique, agile, and real-time solutions that enable immediate, reliable, and reproducible results. Founded in 2009 as a joint venture between the public and private sectors, we combine the latest advances in science and research with cutting-edge technologie

 

After years of experience, we are dedicated to developing accessible High Throughput products. Our first system was Wmicrotracker® ONE, which is based on non-invasive technology that uses infrared microbeams and photosensors. Developed in collaboration with CONICET and protected by international patents, ONE enables the quantification of locomotor activity of small organisms in a 96- or 384-well microplate format. The detection system is compatible with small organisms such as C. elegans, mobile-stage parasites, zebrafish larvae, Drosophila larvae, and artemia salina, among others.

page3image336093840 page3image2636071328

HOW IT WORKS?

page3image2636071120

Based on an innovative system of 384 IR microbeams, the system detects the small interferences generated by the organisms present in the sample.
In this way, a pattern of activity is recorded and processed using software specifically designed for real-time data acquisition.

The digital analysis of signal changes (proportional to light intensity) allows us to detect the movement of the organism as it passes through the beam of light. An algorithmic software calculates the number of activity events per unit time.

The device can perform High Throughput assays in liquid media in the following microplate formats:

-6 wells[30-32 IR led/well]
-24 wells [4 IR led/well]
-96 wells flat bottom [2 IR led/well] -96 pocillos fondo U [1 IR led/well] -384 pocillos [1 IR led/well]

page3image336099328
page3image336091040page3image336087680page3image336100000

ONE

page4image336814176 page4image2636379552

Equipment detection range

page4image2636376224 page4image336820560 page4image2636372480 page4image336807456

A

B

  1. Curve in a 96-well flat-bottomed microplate. The system has a linear detection range between 25 and 100 young adult N2 worms. R2=0.99.

  2. Curve in a 96-well U-bottomed microplate. The system has a linear detection range between 5 and 25 young adult N2 worms. R2=0.97.

  3. Curve in a 384-well microplate. The system has a linear detection range between 1 and 10 young adult N2 worms. R2=0.97
    The bars represent +/- S.D.

page4image2636377888 page4image2636378304

C

page4image336808464 page4image336813616
page4image336820000
page5image2635915808 page5image2635917264

APLICATIONS

Toxicity-Microbiota-Pathogenesis-RNAi-Stress-Neurodegeneration

page5image2635913104
 
 
 
 
 
 
page5image336439024
page6image2635901920 page6image2635904208

APLICATIONS

Toxicity-Microbiota-Pathogenesis-RNAi-Stress-Neurodegeneration

page6image2635892976
page6image336850976 page6image2635897968
page7image2636759664 page7image2637153296

APLICATIONS

Toxicity-Microbiota-Pathogenesis-RNAi-Stress-Neurodegeneration

page7image2636297632
 
 
 
 
 
 
page7image338303776
page8image2636240160 page8image2636244112

APLICATIONS

Toxicity-Microbiota-Pathogenesis-RNAi-Stress-Neurodegeneration

page8image2636237040
 
 
 
 

Measurement of the effect of PTZ on Zebrafish larvae as a pharmacological model of epilepsy.

Effect of PTZ on the behavior of 5-dpf (days post fertilization) zebrafish larvae, after a 15-minute exposure. The graph shows the tracking of swimming behavior and distance (in mm) for each fish cultured in a 6-well microplate. An increase in the total distance traveled by the fish in the presence of the convulsant agent is observed

page8image336488848page8image2636239744
page9image336498848 page9image2635991696

COMPONENTS INCLUDED

page9image2635991904page9image2635992112 page9image336500640

Measurements

page9image336499968 page9image2635993152

Requirements

page9image336499072
page9image336498624
bio-equip.com
售后服务
相关视频
资料下载
快速询价登录注册在线询价 (请留下您的联系方式,以便供应商联系您)
* 姓  名:
* 地  区:
* 单  位:
职  位:
* 手机/电话:
* E-mail:
请寄产品资料:
需要 不需要
请报价格:
需要报价 不需要报价
留  言:
验证码:
换一张
发表评论在线评论(0条)
手机版:Wmicrotracker ONE
Copyright(C) 1998-2025 生物器材网 电话:021-64166852;13621656896 E-mail:info@bio-equip.com
立即询价